Contact

 

ADD:The South Industrial Park, Tangligou, Hongqi street, Ganjingzi district, Dalian, China

TEL:+86-411-84179933 +86-411-84179922

FAX: +86-411-84179900

EMAIL:info@tuf-2000.com

WEB :www.tuf-2000.com

product

The current position : index > product display

Inline ultrasonic heat meter

 
Model:TUF-2000F
 
 
  • Illustrations
  • Detailed Parameters
 

Measuring Diagram:

 

Both the meter and transducer are installed in the pipeline, level of protection reach to IP68.

Optional types of transducers, measuring range from DN50 ~ DN6000mm. 

 

heat meter pipe.jpg 




Features of the meter:


 Working Environment


  Main Unit Transducer
Protection Level IP65 IP68
Temperature -20~60 -30~160



Basic Parameters

 

Accuracy

≤1%

Velocity range 0~±10m/s, Bi-directional measurement
Pipe size DN32~DN6000mm
Temperature -30~160
Type of liquid Single liquid can transmit ultrasound, such as water, sea water, sewage, oil, alcohol, etc.
Pipe material Steel, stainless steel, cast iron, copper, PVC, aluminmum, glass steel, etc. Liner is allowed.
Signal output

1 way 4-20mA output

1 way OCT pulse output

1 way Relay output

Signal input 3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor.
Interface RS485, support MODBUS
Data storage SD card regularly store the pre-set results(optional)
Power supply

DC8~36V or AC10~30V

AC85~264V, waterproof power adapter.


 


Features of Transducers:




Standard Pipe Transducer


  



π type pipe Transducer 




Threaded Connection





Flange Connection







High temperature insertion transducer

HTB1HzXmJXXXXXaDXpXXq6xXFXXXT 




 

ADD:The South Industrial Park, Tangligou, Hongqi street, Ganjingzi district, Dalian, China

TEL:+86-411-84179933 +86-411-84179922  FAX: +86-411-84179900