Classification
Picture | Description | Model | Measuring Range | Depth | Temperature Range | Installation Requirement |
|
Insertion PT100/PT1000 Small size pipe diameter |
SCT-1 | <DN50 | 30MM | -30~160℃ | Need to cut off water |
|
Insertion temperature Transducer Pt100 |
TCT-1 | DN50~DN150 | 105MM | -30~160℃ | |
DN200~DN250 | 140MM | -30~160℃ | ||||
≥DN300 | 210MM | -30~160℃ | ||||
|
Insertion Pt100 Installation with pressure |
TCT-2 | DN50~DN150 | 210MM | -30~160℃ | Need to cut off water , mainly used for battery powered ultrasonic flowmeter |
|
|
|
||||
|
|
|
Features
1. Insert temperature transducer contact with the liquid directly, improve the measurement accuracy and converter stability
2. PT10,PT1000 for selection
3.Measuring temperature Range:-30~160℃, Measuring Accuracy: 100℃,±0.8℃.