Insert temperature transducer

 
Model:PT100/PT1000
Can finish the temperature and heat measurement if you connect with the ultrasonic flowmeter
 
 
  • Illustrations
  • Detailed Parameters
 

Classification

Picture Description Model Measuring Range Depth Temperature Range Installation Requirement

Insertion PT100/PT1000
Small size pipe diameter
SCT-1 <DN50 30MM -30160℃ Need to cut off water

Insertion temperature
Transducer Pt100
TCT-1 DN50DN150 105MM -30160℃
DN200DN250 140MM -30160℃
≥DN300 210MM -30160℃

Insertion Pt100
Installation with pressure
TCT-2 DN50DN150 210MM -30160℃ Need to cut off water , mainly used for battery powered ultrasonic flowmeter






Features

 1. Insert temperature transducer contact with the liquid directly, improve the measurement accuracy and converter stability
 2. PT10,PT1000 for selection
 3.Measuring temperature Range:-30~160℃, Measuring Accuracy: 100℃,±0.8℃.

 